GTM>

GTM>D Q^DI

MSC FileMan 22.1030

Select OPTION: 1 ENTER OR EDIT FILE ENTRIES

Input to what File: KERNEL SYSTEM PARAMETERS// taskman site parameters

(1 entry)

EDIT WHICH FIELD: ALL//

Select TASKMAN SITE PARAMETERS BOX-VOLUME PAIR: DEMO:localhost

Are you adding 'DEMO:localhost' as

a new TASKMAN SITE PARAMETERS (the 2ND)? No// (No) ??

Select TASKMAN SITE PARAMETERS BOX-VOLUME PAIR: ?

Answer with TASKMAN SITE PARAMETERS BOX-VOLUME PAIR:

DEMO:openvista-appliance

You may enter a new TASKMAN SITE PARAMETERS, if you wish

Answer must be 3-30 characters in length.

The value for the current account is DEMO:localhost

Select TASKMAN SITE PARAMETERS BOX-VOLUME PAIR: ?

Answer with TASKMAN SITE PARAMETERS BOX-VOLUME PAIR:

DEMO:openvista-appliance

You may enter a new TASKMAN SITE PARAMETERS, if you wish

Answer must be 3-30 characters in length.

The value for the current account is DEMO:localhost

Select TASKMAN SITE PARAMETERS BOX-VOLUME PAIR: DEMO:openvista-appliance

BOX-VOLUME PAIR: DEMO:openvista-appliance Replace

RESERVED: ?

Choose from:

Y YES

N NO

RESERVED: y YES

LOG TASKS?: y YES

DEFAULT TASK PRIORITY: [3~^LOG TASKS??

DEFAULT TASK PRIORITY: ^LOG TASKS?

LOG TASKS?: YES// y YES

DEFAULT TASK PRIORITY: ?

Type a Number between 1 and 10, 0 Decimal Digits

DEFAULT TASK PRIORITY: 1

TASK PARTITION SIZE: ?

Enter the number of KB (10-999) to set maximum partition size to.

TASK PARTITION SIZE: 999

SUBMANAGER RETENTION TIME: ?

Type a Number between 0 and 600, 0 Decimal Digits

SUBMANAGER RETENTION TIME: 600

TASKMAN JOB LIMIT: 999// 999

TASKMAN HANG BETWEEN NEW JOBS: 0// ?

Type a Number between 0 and 10, 0 Decimal Digits

TASKMAN HANG BETWEEN NEW JOBS: 0//

MODE OF TASKMAN: GENERAL PROCESSOR// ?

This is a required field.

Enter '??' for more help.

Choose from:

G GENERAL PROCESSOR

P PRINT SERVER

C COMPUTE SERVER

O OTHER NON-TASKMAN

MODE OF TASKMAN: GENERAL PROCESSOR//

VAX DSM ENVIROMENT FOR DCL: ?

Answer must be 2-12 characters in length.

VAX DSM ENVIROMENT FOR DCL:

OUT OF SERVICE: NO//

MIN SUBMANAGER CNT: ?

Type a Number between 0 and 99, 0 Decimal Digits

MIN SUBMANAGER CNT:

TM MASTER: ?

Answer with TASKMAN SITE PARAMETERS BOX-VOLUME PAIR:

DEMO:openvista-appliance

TM MASTER: DEMO:openvista-appliance

Balance Interval: ?

Type a number between 10 and 120, 0 Decimal Digits

Balance Interval: 10

LOAD BALANCE ROUTINE: ?

Answer must be 3-40 characters in length. Funtion, Extrinsic function,

External routine.

LOAD BALANCE ROUTINE:

Auto Delete Tasks: Yes// ?

Choose from:

0 No

1 Yes

Auto Delete Tasks: Yes//

Manager Startup Delay: 3//

Select TASKMAN SITE PARAMETERS BOX-VOLUME PAIR: ?

Answer with TASKMAN SITE PARAMETERS BOX-VOLUME PAIR:

DEMO:openvista-appliance

You may enter a new TASKMAN SITE PARAMETERS, if you wish

Answer must be 3-30 characters in length.

The value for the current account is DEMO:localhost

Select TASKMAN SITE PARAMETERS BOX-VOLUME PAIR: ^

Select OPTION: